Click image to enlarge
The V-PLEX SARS-CoV-2 Panel 27 (Mouse IgG) Kit is a qualitative multiplex serology assay for mouse antibodies to Spike antigens from variants of SARS-CoV-2. It includes antigens from Beta, Delta, and several sublineages of Omicron, including BA.2, BA.2.12.1, BA.3, BA.4, BA.5, and two BA.2 Spike antigens with extra mutations predicted to further evade neutralization. Panel 27 includes: A (WT), (B.1.351), (B.1.617.2; AY.4) Alt Seq 2, (BA.2; BA.2.1; BA.2.2; BA.2.3; BA.2.5; BA.2.6; BA.2.7; BA.2.8; BA.2.10; BA.2.10.1; BA.2.12), (BA.2.12.1), (BA.2+L452M), (BA.2+L452R), (BA.3), (BA.4), and (BA.5).
Note: Alternative S-GENE mutations for Spike of B.1.617.2 are listed as "Alt Seq #."
-
-
Specifications
-
Kit Contents
-
Documentation
-
References
Analyte(s)
|
|
SARS-CoV-2 Spike, SARS-CoV-2 Spike (B.1.351), SARS-CoV-2 Spike (B.1.617.2; AY.4), SARS-CoV-2 Spike (BA.2), SARS-CoV-2 Spike (BA.2.12.1), SARS-CoV-2 Spike (BA.2+L452M), SARS-CoV-2 Spike (BA.2+L452R), SARS-CoV-2 Spike (BA.3), SARS-CoV-2 Spike (BA.4), SARS-CoV-2 Spike (BA.5)
|
|
Species
|
|
Mouse
|
|
Instrument(s)
|
|
SECTOR Imager 2400
,
MESO QuickPlex SQ 120MM
,
MESO SECTOR S 600
,
SECTOR Imager 6000
,
MESO SECTOR S 600MM
,
MESO QuickPlex SQ 120
|
|
Plate Type
|
|
96-well
|
|
Sample Type
|
|
Serum, Plasma
|
|
Usage Statement
|
|
For Research Use Only. Not for use in diagnostic procedures.
|
|
Storage Condition
|
|
Multi-Component
|
|
Schedule B Code
|
|
3822.19.0000
|
|
Product Description
|
Storage
|
Quantity per Kit
|
SULFO-TAG Anti-Mouse IgG Antibody, 5 Plate
|
2-8 °C
|
1 vial (5 plate size)
|
|
SARS-CoV-2 Plate 27
|
2-8 °C
|
5 each (1 each)
|
|
|
2-8 °C
|
1 bottle (200 mL)
|
|
|
RT
|
1 bottle (90 mL)
|
|
|
RT
|
1 bottle (100 mL)
|
|
MSD Blocker A
|
RT
|
1 bottle (250 mL)
|
|
MSD Phosphate Buffer 5X
|
RT
|
1 bottle (50 mL)
|
|
Product Description
|
Storage
|
Quantity per Kit
|
SULFO-TAG Anti-Mouse IgG Antibody, 5 Plate
|
2-8 °C
|
5 vial (5 plate size)
|
|
SARS-CoV-2 Plate 27
|
2-8 °C
|
25 each (1 each)
|
|
|
2-8 °C
|
5 bottle (200 mL)
|
|
|
RT
|
5 bottle (90 mL)
|
|
|
RT
|
5 bottle (100 mL)
|
|
MSD Blocker A
|
RT
|
5 bottle (250 mL)
|
|
MSD Phosphate Buffer 5X
|
RT
|
5 bottle (50 mL)
|
|
Product Inserts
|
|
|
Handouts
|
|
|
Certificate of analysis
|
|
|
SDS
|
|
|
Title
|
Journal
|
Year
|
|
IgG Anti-Spike Antibodies and Surrogate Neutralizing Antibody Levels Decline Faster 3 to 10 Months After BNT162b2 Vaccination Than After SARS-CoV-2 Infection in Healthcare Workers
|
|
|
|
Immune responses after omicron infection in triple-vaccinated health-care workers with and without previous SARS-CoV-2 infection
|
|
|
|
Performance and validation of an adaptable multiplex assay for detection of serologic response to SARS-CoV-2 infection or vaccination
|
|
|
|
Sensitive Serology Measurements in the Saliva of Individuals with COVID-19 Symptoms Using a Multiplexed Immunoassay
|
|
|
|
Quantitative serology for SARS-CoV-2 using self-collected saliva and finger-stick blood
|
|
|
|
View All
|
Order Details
Catalog No
Size
Price in USD
Qty
Customer Service/Orders
Scientific/Technical Support
Instrument Support
Company Headquarters