Click image to enlarge
S-PLEX is MSD’s ultrasensitive assay platform. It can dramatically improve the sensitivity of immunoassays, reducing the lower limit of detection (LLOD) by 10- to 1000-fold over other assay methods. The S-PLEX Human Tau (pT217) Assay has the essential components for an ultrasensitive assay that measures phosphorylated Tau at threonine 217 in a single-analyte format. For detailed instructions on running the Tau (pT217) assay, please see the product insert in the "Documentation" tab below.
Related Key Terms: MAPT, microtubule-associated protein tau, Phospho Tau-217, Phosphorylated Tau, pTau217, pTau-217, Threonine217, Alzheimer’s disease, neurodegeneration, neurology
-
-
Specifications
-
Kit Contents
-
Documentation
-
References
Application(s)
|
|
Neurobiology/Neurodegeneration
,
Alzheimer’s Disease
|
|
Analyte(s)
|
|
Tau (pT217)
|
|
Species
|
|
Human
|
|
Instrument(s)
|
|
SECTOR Imager 2400
,
MESO QuickPlex SQ 120MM
,
MESO SECTOR S 600
,
SECTOR Imager 6000
,
MESO SECTOR S 600MM
,
MESO QuickPlex SQ 120
|
|
Plate Type
|
|
96-well
|
|
Capture Antibody
|
|
Mouse monoclonal
|
|
Detection Antibody
|
|
Mouse monoclonal
|
|
LLOD (Sensitivity)
|
|
880 fg/mL
|
|
Dynamic Range
|
|
880 - 3,590,000 fg/mL
|
|
Sample Type
|
|
Serum, Plasma, CSF, Urine, Cell Culture Supernatant
|
|
Recombinant standards
|
|
Expressed in Human cell line
|
|
Usage Statement
|
|
For Research Use Only. Not for use in diagnostic procedures.
|
|
Storage Condition
|
|
Multi-Component
|
|
Gene ID(s)
|
|
4137
|
|
UniProt ID(s)
|
|
P10636
|
|
Schedule B Code
|
|
3822.19.0000
|
|
Product Description
|
Storage
|
Quantity per Kit
|
Diluent 2
|
≤-10 °C
|
1 each (8 mL)
|
|
S-PLEX Human Tau (pT217) Antibody Set
|
2-8 °C
|
1 each (1 plate size)
|
|
Human Tau (pT217) Calibrator
|
≤-70 °C
|
1 vial (1 vial)
|
|
S-PLEX Coating Reagent C1
|
≤-70 °C
|
1 vial (300 μL)
|
|
S-PLEX Detect D2
|
≤-70 °C
|
1 each (50 μL)
|
|
S-PLEX Detect D1
|
≤-70 °C
|
1 each (1.7 mL)
|
|
S-PLEX 96-Well SECTOR Plate
|
2-8 °C
|
1 each (1 plate)
|
|
|
2-8 °C
|
1 bottle (50 mL)
|
|
|
2-8 °C
|
1 bottle (8 mL)
|
|
|
RT
|
1 bottle (18 mL)
|
|
S-PLEX Enhance E1
|
≤-10 °C
|
1 each (1.7 mL)
|
|
S-PLEX Enhance E2
|
≤-10 °C
|
1 vial (1.7 mL)
|
|
S-PLEX Enhance E3
|
≤-70 °C
|
1 each (50 μL)
|
|
|
≤-10 °C
|
1 vial (500 μL)
|
|
Product Description
|
Storage
|
Quantity per Kit
|
Diluent 2
|
≤-10 °C
|
1 each (40 mL)
|
|
S-PLEX Human Tau (pT217) Antibody Set
|
2-8 °C
|
1 each (5 plate size)
|
|
Human Tau (pT217) Calibrator
|
≤-70 °C
|
5 vial (1 vial)
|
|
S-PLEX Coating Reagent C1
|
≤-70 °C
|
1 vial (300 μL)
|
|
S-PLEX Detect D2
|
≤-70 °C
|
5 each (50 μL)
|
|
S-PLEX Detect D1
|
≤-70 °C
|
5 each (1.7 mL)
|
|
S-PLEX 96-Well SECTOR Plate
|
2-8 °C
|
5 each (1 plate)
|
|
|
2-8 °C
|
1 bottle (50 mL)
|
|
|
2-8 °C
|
1 bottle (40 mL)
|
|
|
RT
|
1 bottle (90 mL)
|
|
S-PLEX Enhance E1
|
≤-10 °C
|
5 each (1.7 mL)
|
|
S-PLEX Enhance E2
|
≤-10 °C
|
5 vial (1.7 mL)
|
|
S-PLEX Enhance E3
|
≤-70 °C
|
5 each (50 μL)
|
|
|
≤-10 °C
|
1 vial (500 μL)
|
|
Product Description
|
Storage
|
Quantity per Kit
|
Diluent 2
|
≤-10 °C
|
5 each (40 mL)
|
|
S-PLEX Human Tau (pT217) Antibody Set
|
2-8 °C
|
5 each (5 plate size)
|
|
Human Tau (pT217) Calibrator
|
≤-70 °C
|
25 vial (1 vial)
|
|
S-PLEX Coating Reagent C1
|
≤-70 °C
|
5 vial (300 μL)
|
|
S-PLEX Detect D2
|
≤-70 °C
|
25 each (50 μL)
|
|
S-PLEX Detect D1
|
≤-70 °C
|
25 each (1.7 mL)
|
|
S-PLEX 96-Well SECTOR Plate
|
2-8 °C
|
25 each (1 plate)
|
|
|
2-8 °C
|
5 bottle (50 mL)
|
|
|
2-8 °C
|
5 bottle (40 mL)
|
|
|
RT
|
5 bottle (90 mL)
|
|
S-PLEX Enhance E1
|
≤-10 °C
|
25 each (1.7 mL)
|
|
S-PLEX Enhance E2
|
≤-10 °C
|
25 vial (1.7 mL)
|
|
S-PLEX Enhance E3
|
≤-70 °C
|
25 each (50 μL)
|
|
|
≤-10 °C
|
5 vial (500 μL)
|
|
Product Inserts
|
|
|
Certificate of analysis
|
|
|
SDS
|
|
|
Scientific Posters
|
|
|
Title
|
Journal
|
Year
|
|
Performance of plasma p-tau217 for the detection of amyloid-β positivity in a memory clinic cohort using an electrochemiluminescence immunoassay
|
|
|
|
|
Order Details
Catalog No
Size
Price in USD
Qty
Customer Service/Orders
Scientific/Technical Support
Instrument Support
Company Headquarters